Application

Designed for SENS software connection to PC or controller via RS-232,RS-485 or USB interface connection using SENS and Modbus-RTU protocols. SENS devices adjustment is executed via SENS protocol. Data exchange is executed via ModBus RTU protocol (adapter plays a roleof a SLAVE device in Modbus network) Range and technical features are given in table. 1, connection schemes - pic. 5...12.

Features

 

 

                    

 

 

 

 

 

Adapter designation   

LIN-RS485/232

LIN-RS485-24B*

LIN-RS232-24B*

LIN-RS232

LIN-RS485

LIN-RS232-12/24B

LIN-RS485Modbus-12/24B

Output interface

RS-232  or RS-485

RS-485  or RS-232

RS-232 

RS-232 

RS-485  or RS-232

RS-232 

RS-485  or RS-232

Data exchange protocol

SENS/MODBUS

MODBUS

SENS

SENS

MODBUS

SENS

MODBUS

Power supply voltage, V

6…13 SENS software

10…32

6…13 SENS software

9…28

Consumed power, W, not exceeding

-

Consumed curent, mA

30

200 max

35

190 max

Output voltage, V

-

8+-0,2

-

7

Load curent, A, not exceeding

-

0.4

-

0.09

Housing type, pic. …

1

2B

Housing material: UP – shock-resistant polysterene, St – 13Mn6 steel

UP

Connection scheme, pic.…

5

cm. OM

6

7

8

9

Explosion protection marking

-

Ambient air temerature range, C

-20…50

-40…60

5…60

Климатическое исполнение по ГОСТ 15150

-

Water and dust ingress protection

IP20

IP40

Overall dimensions, mm

85х67х17,5

106х68х32,7

65х65х57

94х94х57

Average lifetime, years, not less than

10

 

 

                    

 

 

 

 

 

Adapter designation   

LIN-RS232-220B

LIN-RS485Modbus-220V

VUUK-2KV-LIN-RS232

VUUK-2KV-LIN-RS485Modbus

VUUK-3KV-SV-LIN-RS232-12/24V

VUUK-3KV-SV-LINRS232-220V

LIN-USV

Output interface

RS-232 

RS-485  or RS-232

RS-232 

RS-485  or RS-232

RS-232 

RS-232 

USB

Data exchange protocol

SENS

MODBUS

SENS

MODBUS

SENS

SENS

SENS

Power voltage, V

~220V

6…13 SENS software

9…28

~220V

6…13 SENS software

Consumed power, W, not exceeding

0,5 (1,5 max)

-

0,5 (1,5 max)

-

Consumed curent, mA

-

35

190

-

5 5 for SENS, 10 for USB

Output voltage, V

6-10%

-

7

6-10%

-

Load curent, A, not exceeding

0.05

-

0.09

0.05

-

Housing type, pic. …

Housing material: UP – shock-resistant polysterene, St – 13Mn6 steel

UP

 

St

 

UP

Connection scheme, pic.…

10

11

6

7

8

10

12

Explosion protection marking

-

1ExdIIBT4

-

Ambient air temerature range, C

5…60

-40…60

5…60

-

УХЛ1

-

Water and dust ingress protection

IP40

IP66

IP54

Overall dimensions, mm

94х94х57

125х155х70

94х94х57

Average lifetime, years, not less than

10

Designation

Adapters are designated: LIN-RS485/232, LIN-RS485-24В, LIN-RS232-24В, LIN-RS232, LIN-R485, LIN-R232-12/24В, LIN-R485Modbus-12/24В, LIN-R232-220В, LIN-R485Modbus-220В, VUUK-2KV-LIN-RS232, VUUK-2KV-LIN-RS485Modbus, VUUK-3KV-SV-LIN-RS232-12/24V, VUUK-3KV-SV-LIN-RS232-220V, LIN-USB.