SENS SG-A1 gas detector
Remote measurement of under-explosive concentrations of combustible gases and vapors of petroleum products.

Specifications

Detectable componentspropane, methane, butane, hexane
Verification gasespropane, methane
Measurement range, % of LELfrom 0 to 100
Principle of measurementoptical absorption
Interval between verifications, months24; 12 (for model on -60 ℃)
Indications setting time (T90), s, not more than60
Heating time, s, not more than120;
3600 (for model on -60 ℃)
Nominal power supply voltage (DC), V9;
27 (for model on -60 ℃)
Acceptable power supply voltage (DC), Vfrom 4.5 to 30 1)
Power consumption, W, not more than2.5; 20 (for model on -60 ℃)
Interfaces (protocols)power and signal line SENS (SENS protocol),
RS-485 (protocols SENS, Modbus RTU),
4-20 mA (HART protocol)
Signal relay features:maximal switchable DC/AC voltage, V30 / 42
maximal switchable current, A0.5
Number of configurable thresholds of alarm signaling5
Diameter of connectible cable without armor, mmfrom 5 to 18
Maximal cross-sectional area of connectible conductors, mm², not more than2.5
Materials contacting the environmentAlSi7 (analogue of AlSi7Mg), steel 20, steel 12Cr18Ni10Ti, steel 14Cr17Ni2, AISI 431
Main absolute inaccuracy within range from 0 to 60% level measurement of LEL, % LEL, not more than±3
Main relative inaccuracy of measurement withing range from 60 to 100% LFL, %, not more than±5
Ambient temperature range, ℃from -40 (-60) to +60
Protection degree as per GOST 14254IP66
Explosion-proof marking1Ex db IIB T6 Gb;
1Ex db IIB T4 Gb X (for model on -60 ℃)
Overall dimensions W x H x D, mm, not more than240 × 240 × 170
Mass, kg, not more3; 4 (for model on -60 ℃)
Service life, years15
Mean time between failures, hours, not less than15000

Note.

1) when the unit is equipped with "SENS" interface maximal power voltage is limited to 18V