- Info
- Specifications
- Additional info 6
Specifications
| Number of control levels | 1 or 2 (on order) | ||
|---|---|---|---|
| Guide pipe length (horizontal part), mm | Up to 1000 | ||
| Output terminals | W5, W30, DC24, AC24, AC220 | ||
| Limits of control level setting tolerance, mm | ±5; ±2 – on order | ||
| Monitored media features | temperature, ℃ | from -50 (only for non-freezing media) up to +60 (up to +125 - as per Customer’s request) | |
| pressure, MPa, not more than | 2.5 (up to 10 – as per Customer’s request) | ||
| density, kg/m³, not less than | 450 | ||
| Ambient temperature range, ℃ | from -50 to +60 | ||
| Water and dust ingress protection degree as per IEC 60529 | IР66 | ||
| Explosion protection marking as per IEC 60079-26:2006 | Ga/Gb Еx db IIB Т3 | ||
| Mean time between failures, hours, not less | 50 000 | ||
| Service life, years | 10 | ||