Top.Mail.Ru
PMP-022 magnetic float converter
Monitoring of floating roof tanks overfilling. Output - «dry» contact.

Specifications

Number of control levels1
Output terminalsdb: W5, W5DNC, W30, DC24, AC24, AC220, NAMUR;
ia+db: W5, W5DNC, NAMUR;
0Ex+db: W5, W5DNC, NAMUR.
Limits of control level setting tolerance, mm±5
Monitored media featurestemperature, ℃from -50 to +60 (for non-freezing)
pressure, MPa, not more than2.5
density, kg/m³from 450
Temperature for operation, storage and transportation, ℃from -50 to +60
Spring compression cycles quantity, not less15 000
Water and dust ingress protection degree as per GOST 14254 (IEC 60529)IP66
Explosion protection markingGa/Gb Ex db IIB T3, Ga/Gb Ex ia IIB T6, 0Ex ia IIB T6 Ga
Designated service life period, years15
Mean time between failures, h, not less than100 000
Weight, kg, not more than10 (without mounting type)