Nominal diameter (DN), mm15202532405080100
Effective diameter, mm15202532405080
Nominal pressure (PN), kgf/cm²16; 25; 40
Pressure difference (ΔP) for direct thrust, kgf/cm²from 0 to PN
Pressure difference (ΔP) for inverted thrust, kgf/cm²not applied 1)
Working pressure, kgf/cm²1.5·PN
Closing mechanism sealing according to GOST R 54808«A» class
Seal typemetal - fluoroplastic
Supply voltage
220 V (AC/DC)110 V (DC)24 V (DC)
Consumed power (PF / PHold), W
300 / 10300 / 10200 / 10
Operation length, %100
Activation frequency, cycle/min, not more than6
Operational media temperature, ℃from -50 to +80 (short-time operation up to 100)
from 5 to 195 - for «200C» design
Ambient temperature, ℃from -50 (from -60 - on order) to +60
Explosion protection markingnon-electrical part: 1Ex h IIC T6 Gb X; 1Ex h IIC T6...T3 Gb X (only for «-200C» model)
actuator and end position sensor SENS-DKP: 1Ex db IIC T4 Gb X
Orientation on the pipelinewith actuator facing up ±90° (with actuator in horizontal position – for «-200C» design)
Process connectionflange design F according to GOST 33259-2015 (other – on order)
Overall dimensions, mmA, not more than318325338345399404481486
B, not more than294294294294346343386391
C132132196196230230308308
Overall dimensions of "DKP" design, mmA, not more than383390403410461463548555
B, not more than358358358358400402453458
C132132196196230230308308
Overall dimensions of «200C» design, mmA, not more than368375388395447449533538
B, not more than344344344344386388438443
C132132196196230230308308
Overall dimensions of «DKP-200C» design, mmA, not more than428435448455507509586591
C, not more than404404404404446448491496
C132132196196230230308308
Weight, kg, not more than1415181924254041
Full service life, years40

Note.

1) When pressure is supplied in the opposite direction, the valve without a reverse sealing device will be opened