| Nominal diameter of large passage (DN1), mm | 80 |
|---|
| Nominal diameter of small passage (DN2), mm | 10 | 25 | 32 | 0-32 |
|---|
| Nominal pressure (PN), kgf/cm² | 25 |
|---|
| Pressure difference (ΔP) for direct thrust, kgf/cm² | from 1 to 25 |
|---|
| Pressure difference (ΔP) for inverted thrust, kgf/cm² | not applied |
|---|
| Working pressure, kgf/cm² | 38 |
|---|
| Closing mechanisms sealing according to GOST R 54808 | «A» class |
|---|
| Seal type | — |
|---|
| Case material | steel 10Kh18N9L |
|---|
| Supply voltage | | ~ 220 V, 50 Hz | 24 V (on order) |
|
|---|
| Nominal consumed power, W | — |
|---|
| Operation length, % | 100 |
|---|
| Activation frequency, cycle/min, not more than | — |
|---|
| Operational media temperature, ℃ | from -50 to +80 |
|---|
| Ambient temperature, ℃ | from -50 to +60 |
|---|
| Explosion protection marking | 1Ex d IIC T4 Gb X, Ex (ISO/DIS 80079-36) IIC T6 Gb X |
|---|
| Orientation on the pipeline | with actuator of larger passage facing up ±90° |
|---|
| Process connection | flange design F according to GOST 33259-2015 (other – on order) |
|---|
Overall dimensions, mm | A, not more than | 471 | 471 | 471 | 471 |
|---|
| B, not more than | 250 | 250 | 250 | 250 |
|---|
| C | 308 | 308 | 308 | 308 |
|---|
| Weight, kg, not more than | 36 |
|---|
| Full service life, years | 40 |
|---|