Top.Mail.Ru
PMP-063 level gauge
Reed switch. Analog output: 4-20 мА. HART protocol.

Specifications

Guide pipe length, mmfrom 100 to 6000;
from 100 to 2500 (transport modification)
Liquid level measurement step, mm5
Acceptable main inaccuracy of level measurement (for current signal 4 - 20 mA)±5 mm or ±0.15 (±0,1) % of the output signal range (higher value is assumed)
Temperature inaccuracy, % / 10 ℃0.2
Monitored media featurestemperature, ℃from -50 (only for non-freezing media) up to +100 (up to +125 - as per Customer’s request)
pressure, MPa, not more than2.5
density, kg/m³from 450 to 1500 (gasoline, diesel fuel, LPG, petroleum, kerosene, odorant, etc.)
Upper / lower non-metering areas, mm, not less than50 / 50 (depends on a float type)
Temperature for operation, storage and transportation, ℃from -50 to +60
Output signal4-20 mA (HART)
Power supply voltage (Up), Vfrom 9 to 42 (up to 30 – for explosion protection 0Ex ia IIB T5 Ga X)
Reverse polarity voltage protectionavailable
Water and dust ingress protection degree as per GOST 14254 (IEC 60529)IP66
Explosion protection markingGa/Gb Ex d IIВ ТЗ;
0Ex ia IIB T6...T4 Ga X (PMP-063I);
Ga/Gb Ex db IIB T6...T4 X (PVDF-design)
Designated service life period, years15
Mean time between failures, h, not less than100 000
Weight, kg, not more than25