PMP-118 level gauge
Reed switch. Measurement of liquid level and temperature, calculation of volume, density and weight.

Specifications

Guide pipe length, mm:main variantfrom 100 to 6000
transport variantfrom 100 to 2500
inverted variantfrom 100 to 2000
Acceptable main inaccuracy of level measurement, mm±5
Limits for accepted absolute accuracy for temperature measurement, ℃±0.5 (in range from -40 to +105)
±1 (in range from -50 to - 40 and from 105 to 125)
Monitored media features:temperature, ℃from -50 to +100 (up to +125 - as per Customer’s request)
pressure, MPa, not more than2.5 (10 – as per Customer's request)
density, kg/m³from 450 to 1500 (gasoline, diesel fuel, LPG, petroleum, kerosene, odorant, etc.)
Temperature for operation, storage and transportation, ℃from -50 to +60
Water and dust ingress protection degree (IEC 60529)IP66
Explosion protection markingGa/Gb Ex db IIB T3; Ga/Gb Ex d IIB T3
Length of power and signal line, m, not more than length of signal line1500 (SENS); 1200 (RS-485)
Power supply voltage (Up), VDC: from 4 to 15 (SENS); from 6 to 36 (RS-485)
Power consumption, mW, not more than100 (SENS); 400 (RS-485)
Weight, kg, not more than25
Service life, years15
Mean time between failures, hours, not less than100 000