Specifications

Number of control levelsfrom 1 to 4 (on order)
Guide pipe length, mm, not more than6000 (for main variants);
2500 (for transport variants)
Output terminalsW5, W30, DC24, AC24, AC220, КТ, NAMUR
Limits of control level setting tolerance, mm±5; ±2 – on order
Monitored media features:temperature, ℃from -50 (only for non-freezing media) up to +100 (up to +125 - as per Customer’s request)
pressure, MPa, not more than2.5 (10 – as per Customer’s request)
density, kg/m³, not less than450
Ambient temperature range, ℃from -50 (from -60 as per Customer's request) to +60
Water and dust ingress protection degree as per IEC 60529IP66
Explosion protection marking as per IEC 60079-26:2006Ga/Gb Еx db IIВ Т3 (Ga/Gb Ex d IIB T4 X;
0Ex ia IIB T4 Ga X; Ga Ex d+ib IIB T4 X – on order)
Mean time between failures, hours, not less100 000
Service life, years10