Top.Mail.Ru

Specifications

Modelbasic «-Modbus»
Length of a sensing element, mmfrom 50 to 6 000
Materials contacting the mediumsteel 12Cr18Ni10Ti
Number of temperature measurement points, pcsfrom 1 to 81
Limits for accepted absolute accuracy for temperature measurement, ℃±0.5 (in range from -20 to +70); ±2 (in range from -50 to -20)±0.5 (in range from -40 to +100); ±1 (in range from -50 to -40)
Monitored media featurestemperature, ℃from -50 to +100 (+125)
pressure, MPa, not more than10
Климатическое исполнение по ГОСТ 15150
Ambient temperature range, ℃from -50 to +60
Class of human protection against electric shock as per GOST 12.2.007.0
Length of power and signal line, m, not more than length of signal line1 500
Power supply voltage (Up), Vfrom 5 to 15 (DC), nominal 9 (DC)from 6 to 30 (DC)
Intake current, mA, not more than5
Power consumption, W, not more than0,045
Water and dust ingress protection degree as per GOST 14254 (IEC 60529)IP66
Explosion protection marking0/1 Ex db IIB T3 Ga/Gb
Designated service life period, years15