Specifications

Modelbasic «-Modbus»
Length of a sensing element, mmfrom 50 to 6 000
Materials contacting the mediumsteel 12Cr18Ni10Ti
Number of temperature measurement points, pcsfrom 1 to 81
Limits for accepted absolute accuracy for temperature measurement, ℃±0.5 (in range from -20 to +70); ±2 (in range from -50 to -20)±0.5 (in range from -40 to +100); ±1 (in range from -50 to -40)
Monitored media featurestemperature, ℃from -50 to +100 (+125)
pressure, MPa, not more than10
Климатическое исполнение по ГОСТ 15150
Ambient temperature range, ℃from -50 to +60
Water and dust ingress protection degree as per IEC 60529IP66
Class of human protection against electric shock as per GOST 12.2.007.0
Explosion protection marking0/1 Ex db IIB T3 Ga/Gb
Length of power and signal line, m, not more than length of signal line1 500
Power supply voltage (Up), Vfrom 5 to 15 (DC), nominal 9 (DC)from 6 to 30 (DC)
Intake current, mA, not more than5
Power consumption, W, not more than0,045
Average lifetime, years15