SENS SG-A3 gas analyzer with optical sensor
Remote measurement of under-explosive concentrations of combustible gases and vapors of petroleum products.

Specifications

Detectable componentspropane, methane, butane, hexane
Verification gasespropane, methane
Measurement range, % of LELfrom 0 to 50 (detectable components: butane, hexane)
from 0 to 100 (other detectable components)
Sampling methoddiffusion
Principle of measurementoptical absorption
Interval between verifications, months12
Indications setting time (T90), s, not more than60
Heating time, s, not more than60 (at ambient temperature, from -50 до +80 ℃);
1200 (at ambient temperature from -60 to -50 ℃)
Acceptable power supply voltage (DC), Vfrom 8 to 50
Power consumption, W, not more than7.5
Interfaces (protocols)SENS (SENS),
RS-485 (Modbus RTU),
4-20 mA (HART)
Signal relay features:maximal switchable DC/AC voltage, V250 / 50
maximal switchable current, A3 (AC) / 1 (DC)
Number of configurable thresholds of alarm signaling2
Diameter of connectible cable without armor, mmfrom 5 to 20
Maximal cross-sectional area of connectible conductors, mm², not more than2.5
Climatic modification as per GOST 15150UHL1*
Main absolute inaccuracy within range from 0 to 60% level measurement of LEL, % LEL, not more than±3 (detectable components: propane, methane)
±5 (other detectable components)
Main relative inaccuracy of measurement withing range from 60 to 100% LFL, %, not more than±5 (detectable components: propane, methane)
Ambient temperature range, ℃from -60 to +80
Protection degree as per GOST 14254IP66
Explosion-proof marking1 Ex d IIB T6…T5 Gb Х
Overall dimensions W x H x D, mm, not more than388 × 146 × 116
Mass, kg, not more4 (net) / 5 (gross)
Service life, years15
Mean time between failures, hours, not less than75000