PMP-201 level gauge
Magnetostrictive. Up to 6000 mm. Level, temperature, density, media interface measurement, volume and weight calculation.

Specifications

Record in State registry of measurement instruments24715-14
Measurable parameters of medium
  1. liquid level,m
  2. media interface level (produced water level), m
  3. average liquid temperature, °C
  4. tank infill level, %
  5. liquid volume, m³
  6. product weight, t
  7. product density, g/cm³
  8. main product volume (liquid volume above the produced water level), m³
  9. LPG vapour phase temperature, °C
  10. vapour phase weight, t
  11. liquid phase weight, t
  12. temperature in each measuring point (up to eight measuring points), °C
Guide pipe length, mmfrom 500 to 6 000
from 500 to 3 000 (modification without upper nonmetering zone)
from 500 to 2 500 (transport modification)
from 500 to 2 000 (inverted modification)
Acceptable main inaccuracy of level measurement, mm±1
Controlled medium measurement temperature range, ℃from -50 to +60
Limits for accepted absolute accuracy for temperature measurement, ℃±0.5 (in range from -40 to +60 °C)
±1 (in range from -50 to -40 °C)
Density measurement range, kg/ m³from 500 to 1 500
Acceptable absolute inaccuracy for density measurement, kg/m³±1 (for petroleum products)
±2.5 (for liquefied petroleum gases)
Monitored media features:temperature, ℃from -50 to +60 (for non-freezing)
pressure, MPa, not more than2.5 1)
density, kg/m³from 450 to 1 500 (gasoline, diesel fuel, LPG, petroleum, kerosene, odorant, etc.)
Upper / lower non-metering areas, mm, not less than15 / 25
Limit of relative accuracy for measurement of petroleum products and liquefied petroleum gases weight, %±0.65 (in range from 0 to 120 tons)
±0.5 (in range from 120 tons and more)
Measurement of media interface levelwithin the entire measurement range
Number of control values of medium parameters (level, temperature, density, volume, weight, etc.)8
Temperature for operation, storage and transportation, ℃from -50 to +60
Water and dust ingress protection degree as per IEC 60529IP66
Explosion protection markingGa/Gb Ex db IIB T3
Length of power and signal line, m, not more than length of signal line1500 (SENS)
1200 (RS-485)
Power supply voltage (Up), Vfrom 4 to 15 (SENS)
from 6 to 50 (RS-485)
Power consumption, mW, not more than100 (SENS)
400 (RS-485)
Weight without mounting type, kg, not more than10
Average lifetime, years15

Note.

1) Exact value is determined in accordance with types of fixture element and floats