- Info
- Specifications
- Downloads 3
Specifications
| — | |||
| Guide pipe length, mm | from 1 000 to 15 000 | ||
| Materials contacting the medium | stainless steel AISI 304, tetrafluoroethylene polymer (Teflon) | ||
| Acceptable main inaccuracy of level measurement (for current signal 4 - 20 mA) | ±3 mm or ±0.05 % of measurement range (higher value to be used) for “0” modification; ±2 mm or ±0.05 % of measurement range (higher value to be used) for “1” modification | ||
| Acceptable main inaccuracy for level measurement (for digital signal HART), mm | ±3 mm for “0” modification; ±2 mm for “1” modification | ||
| Monitored media features | temperature, ℃ | from -50 to +100 (for non-freezing) | |
| pressure, MPa, not more than | 0.05 | ||
| density, kg/m³ | from 600 to 1 500 1) | ||
| Upper / lower non-metering areas, mm, not less than | 100 / 100 | ||
| Water and dust ingress protection degree as per IEC 60529 | IP66 | ||
| Explosion protection marking | 0Ex ia IIB T5 Ga X | ||
| Power supply voltage (Up), V | from 9 to 30 (DC) | ||
| Power consumption, W, not more than | 1 | ||
| Weight, kg, not more than | 10 | ||
| Service life, years | 15 | ||
Note. 1) Exact maximal density volume depends on the type of the used float(s) | |||